Subject: Re: [PolySix] Reset Adjustment calibration procedure

From: <backshall1@bellsouth.net>
Date: 2014-01-02

There is a 2-pin socket on the power supply board that the 56k resistor should be connected across. You are replacing the ICs on the 367 board. The test resistor goes on the 376 board.
Don B.
 
Sent: Thursday, January 2, 2014 2:11 PM
Subject: [PolySix] Reset Adjustment calibration procedure
 
 

Quick question, I'm replacing IC5 and IC6 on the KLM-376 board, and I'll need to adjust the Reset Adjustment trimmer.  The service manual says "connect a 56k dummy resistor to the KLM-376 2P plug (male)".  Does this just mean connect both ends of a 56K resistor to test point TP2 on the board, or is there some mystery "2P plug" on the KLM-376 board that I'm just not seeing?  Or should I just turn the trimmer til it seems to work right? :)