Archive of the former Yahoo!Groups mailing list: Discussion about the Korg PolySix synthesizer

previous by date index next by date
previous in topic topic list next in topic

Subject: Clone Calibration: DC Click Noise?!

From: Arturo B <arturo00@hotmail.com>
Date: 2011-02-24

So, I have three KLM-367 clone boards finished and working well. Now onto calibration...

[Back story you can skip] I decided to assemble them and get them all working adequately before I started the calibrating stage. Now, this isn't the first time I've done a calibration on the new boards. I tried a partial calibration few months back when I got my first board up and running, but part way through I decided to stop and wait until I had all the boards done. The process was, how shall I put this politely, infuriating(!) as the instructions were vague at best with things lost in translation and perhaps a few assumptions made by the manual author on the tech/person doing the calibrations and their experience/knowledge.

Now that I'm heading back into calibration mode, I was wondering if any of you guys have a plain English interpretation of the instructions. Something a little more thorough, and less... Engrish.

One of the first things I'm having trouble figuring out is what the heck is DC Click Noise (Step 7)? And where the heck do I read this from? The Main out? A test point? If so, which one? How important is this step?

I'm just starting out so there might be a bunch more questions down the line. Figured I'd start with this one.

Thanks in advance. And thanks again to Andy for helping me get through the assembly and subsequent troubleshooting. You da man!

Arturo....

============================================
Arturo Brisindi

[Musics]

mydadvsyours.com | soundcloud.com/arturo00



[Studios]

galleryrecording.weebly.com | arturo00.weebly.com



[Non-text portions of this message have been removed]