Archive of the former Yahoo!Groups mailing list: Discussion about the Korg PolySix synthesizer

previous by date index next by date
previous in topic topic list next in topic

Subject: Re: [PolySix] Re: (new) KLM-367 Calibration

From: Andrew Jury <andy@networkjabber.com>
Date: 2010-09-13

OK then, so what is the voltage reading on the left-hand base of T3 with the
MG frequency pot at 0 and at 10? Also what is the emitter voltage at with
VR5 fully clockwise/counter clockwise? The tricky part is that the frequency
is determined by the current input at IC21 pin 16, which isn¹t so easy to
measure. But the voltages into the circuit might give us some clues...

Cheers,
A


On 12/09/2010 04:07, "Daniel A" <apophis93@yahoo.com> wrote:
>
> Andy,
>
> yes I am getting the voltage shift from what looks like -4.95 to +4.95. So
> that is correct it appears. My 4.80v estimation was when I had the setting at
> 10 as the manual states for MG calibration. But it does behave as you
> described
>
> - Daniel
>



[Non-text portions of this message have been removed]