Archive of the former Yahoo!Groups mailing list: Discussion about the Korg PolySix synthesizer

previous by date index next by date
previous in topic topic list next in topic

Subject: Re: (new) KLM-367 Calibration

From: "Daniel A" <apophis93@yahoo.com>
Date: 2010-08-27

Thanks Andy,

I am heading out for the weekend and will post results when I return.




> You are looking for 1 volt p-p, but VR2 does nothing and you have 3.8v p-p?

Yes. VR2 is not changing voltage.

> Does decreasing the MG level control do anything to the output? You should
> have this set to 10 when making adjustments here.

The MG level pot does not change the value. It is set at 10 when attempting to calibrate.

> What do you have at IC14
> pin 7 with MG level at 10?

I will have this value posted when I return.

Thanks again for you help.
- Daniel