Archive of the former Yahoo!Groups mailing list: Discussion about the Korg PolySix synthesizer
Subject: Adjustment Procedure problems
From: "aniello.iaccarino" <ani.bliss@gmail.com>
Date: 2010-07-05
Hi Friends
I recently did the adjustment procedure and I found two problems.
The first is: not all the leds BANK A-D, PROGRAMS 1-8, MANUAL and TAPE
ENABLE lights up when i turn VR1 from left to right, but every time I
pass a certain point of VR1 leds light up in different combinations.
[[-(]
I have to say that I can proceed to the calibration procedure anyway.
But I don't know If the result of the calibration procedure could be
better if all leds light up instead some of them.
The second i found is that when I regulate MG speed I can't obtain a
cycle of 10-40 sec, but just 4 sec, a very short cycle. [[-(]
For this problem have I to check IC21 and C19?
Any suggestion? [:D]
Thanks
Aniello
[Non-text portions of this message have been removed]