Hello Achim,
thanks for the tip... It's the explanation of my problem!
(Bonk, bonk, bonk = noise of my head hitting my desk)
In fact, my EX800 is correctly receiving the SYSEX since the beginning, but I was checking the edition buffer content, not the storage RAM. It's exactly the same approach on the Korg DSS1 (you never edit the banks, you edit a local buffer containing one program)... and I did not remember it 8-(
Thanks again for the help
Benoit
--- In korgpolyex@yahoogroups.com, ASSI <Stromeko@...> wrote:
>
> On Tuesday 05 March 2013, 14:10:41, benoitdmx wrote:
> > Here is what I see : if I edit a parameter (let's say param 18, set to 2
> > originally) and I reload the SYX file, the EX800 is clearly ignoring the
> > SYSEX. The data I see in the changed parameters are still the same than
> > BEFORE uploading the SYX file. It looks like the synth is ignoring simply
> > the valid SYSEX data. If I reload the data from cassette interface, it
> > works (the parameters I have changed are restored to original value)
>
> You have to switch to another program and then back to the original one
> before you can see (and hear) the parameter changing. The active parameters
> are apparently stored in a buffer that is not accessible by sysex (it would
> be nice if you could edit that buffer from sysex, but the EX-800 doesn't
> allow that).
>
>
> Regards,
> Achim.
> --
> +<[Q+ Matrix-12 WAVE#46+305 Neuron microQkb Andromeda XTk Blofeld]>+
>
> Wavetables for the Terratec KOMPLEXER:
> http://Synth.Stromeko.net/Downloads.html#KomplexerWaves
>