Archive of the former Yahoo!Groups mailing list: Vintage Simmons Drums (UK) Users Group

previous by date index next by date
previous in topic topic list next in topic

Subject: Re: [Simmons Drums] Voltage conversion of the MTM transformer... ?

From: "WT" <waveterm@...>
Date: 2011-10-03

Looking at the schematics, you only need to have black and orange ( or pink
for 220V ) connected to the fuse/mains switch.

This should work. If it doesn´t the transformer could be toast. You can get
a new one at Elfa.

WT

----- Original Message -----
From: "xylofoam" <lars.frisk@...>
To: <Simmons_Drums@yahoogroups.com>
Sent: Monday, October 03, 2011 1:58 PM
Subject: Re: [Simmons Drums] Voltage conversion of the MTM transformer... ?


> Hehe :-D
>
> // L
>
> --- In Simmons_Drums@yahoogroups.com, jesper <jesper@...> wrote:
>>
>> xylofoam skrev 2011-10-03 10:20:
>> > Hi all,
>> >
>> > I'm trying to convert the original transformer in my MTM unit from 110V
>> > to 240V... According to the service manual the transformer supports all
>> > voltages on the primary core (all colours match the schematics
>> > (black:0V, brown:100V, white:110V, pink:220V and orange:240V)), but
>> > when
>> > I reconfigure the tranfsformer to EU (240V) I get absolutely NOTHING on
>> > either of the secondaries?!
>> > What am I doing wrong? According to the schematics there is only ONE
>> > primay core, but are there really TWO that needs to be in serial, or ?
>>
>> Sell it to me instead. I have 110-feeds to spare. :D
>>
>> --
>> electronically yours, jesper
>>
>> - -- --- ---- ----- ---- --- -- -
>> www.electronic-obsession.se
>>
>
>
>
>
> ------------------------------------
>
> Yahoo! Groups Links
>
>
>