Archive of the former Yahoo!Groups mailing list: Homebrew PCBs

previous by date index next by date
previous in topic topic list next in topic

Subject: Re: [Homebrew_PCBs] copper plating

From: Adam Seychell <adam_seychell@...>
Date: 2003-11-18

Cathode current density (C.D.) normally between 10 ~ 20 mA/sq.cm.
Are you getting hydrogen from the PCB ?
If so then C.D. is too high or copper too low.

To check approx. copper sulfate concentration make up a test
solution of your desired concentration (e.g. 80 g/L CuSO4.5H20)
and put it in a test tube. Then take sample of plating solution
and put into a identical test tube and fill to equal height. Look
though the end of each test tube and compare the color.
This will get you +-20% accuracy which can be good enough.



roel_cnc wrote:
> Hi,
>
> I'm trying to get me bath plating but it isnt working as it should be!
> only thing i got is a dark brown easely wipe of film
> pcb is 10 sq cm power supply gifs 1,8 volts ad 0,7 amps
> also tryt a 5 volt make same result only faster
> have to tell the bath solution is made as adam's style with a
> terracotta pot - acid is pritty blue
>
> gr. Roel
>
>
>
>
> Be sure to visit the group home and check for new Bookmarks and files:
> http://groups.yahoo.com/group/Homebrew_PCBs
>
> To unsubscribe from this group, send an email to:
> Homebrew_PCBs-unsubscribe@yahoogroups.com
>
>
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
>
>